ROYAL AMWAJ SHARED GYM, ANANTARA THE PALM

ROYAL AMWAJ SHARED GYM, ANANTARA THE PALM

Thermal Comfort Diagnostics | HVAC Load Assessment | Technical Advisory

Dubai, UAE | 2025

PROJECT AT A GLANCE

CLIENT
Aspire Lux Jointly Owned Property Management Services
DURATION
15 days
SERVICE
HVAC performance and thermal comfort assessment
PROJECT FACTS
388 m² gym | Site survey | ASHRAE-based load modelling | Technical recommendations
LOCATION
Dubai, UAE
YEAR
2025

PROJECT OVERVIEW

MCUBE Engineering Consultants was engaged to undertake an independent thermal-comfort and HVAC assessment for the shared gym at Anantara The Palm Dubai Resort. The assignment combined site investigation with engineering load analysis to establish a reliable basis for HVAC optimization and future system decisions.

THE REQUIREMENT

The project required a detailed review of cooling demand under representative operating scenarios, reconciliation against the installed HVAC arrangement, and a technically structured recommendation pathway that could distinguish operational optimization from any future capacity-related intervention.

OUR SCOPE

  • Site survey and collection of available as-built HVAC information.
  • ASHRAE-based cooling-load modelling under more than one occupancy scenario.
  • Engineering comparison of modelled cooling demand against the installed system arrangement.
  • Review of key thermal-comfort influences including air distribution, outdoor-air treatment and solar exposure.
  • Preparation of a phased technical recommendations report and verification roadmap.

OUR APPROACH

Rather than defaulting to equipment replacement, MCUBE used scenario-based load modelling and site evidence to separate capacity considerations from air-distribution, controls and envelope-related influences. This created a staged decision framework focused first on optimization and verification, with capacity intervention considered only where technically justified.

KEY TECHNICAL HIGHLIGHTS

THERMAL COMFORT
Independent diagnosis of comfort performance in an active hospitality facility.
LOAD MODELLING
ASHRAE-based modelling using operational and stress-test scenarios.
SOLAR IMPACT
Review of façade and solar-gain influence on occupied zones.
AIR DISTRIBUTION
Assessment of distribution and ventilation effectiveness.
PHASED STRATEGY
Optimization, verification and future capacity planning.
DECISION SUPPORT
Evidence-led basis for retrofit and operational decisions.

ENGINEERING VALUE

  • Independent, engineering-led delivery with clear technical accountability.
  • Structured coordination that reduces ambiguity between design intent and project execution.
  • Traceable review methodology using documented inputs, standards and project criteria.
  • Practical outputs developed to support construction, commissioning, retrofit or approval decisions as applicable.

RESULTS

The client received an evidence-based HVAC optimization roadmap that clarified the relationship between cooling demand, system operation and thermal-comfort performance, supporting targeted action and more informed future investment decisions.

PROJECT GALLERY 

 

About Us

In a region where performance, compliance, and carbon goals are converging, MCube Engineering Consultants was founded to fill a critical gap.

We deliver integrated, high-impact solutions across MEPF design, energy efficiency, sustainability, and smart building technologies.